The short-circuit calculation in Protection Suite is able to calculate unlimited faults types, almost unlimited complexity and include batch calculation for really big data
Protection suite allows the user to define a protection scheme by integrating protective devices into the network model and get digital twin of primary and secondary equipment for calculations and analysis.
Comprehensive library of digital twin Relay models for many manufactures suitable for steady-state, RMS, EMT calculations and allows you to analyze protection coordination and investigate of relay misoperation and corrective action.
Conducting 1000`s of calculations for all predefined conditions on protection coordination, adjustment and sensitivity check. Start from selecting relay and get Settings at the next step. (distance protection, TOC, IOC, Earth fault, Negative OC protection)
Automated settings calculations and verifications for 6-35 kV protection equipment for transformers, lines, electric motors, buses
Easy-to-use electrical equipment fit and automatically protection coordination functionality for complicated generator protection devices with many specific functions
Conducting 1000`s of calculations for all predefined conditions on protection coordination, adjustment and sensitivity check. Start from selecting relay and get Settings at the next step. (AT/Transformers, bus bars, shunt reactor)
Automated calculations and verifications of breaker/Fuse parameters, equipment parameters
Work will be done automatically and in accordance with the guidelines: calculation conditions, fault places, fault types, including arc influence, heat influence on conductors resistance and feed from electric motors (power equipment fits, fuse and protection devices calculations)
Step-by-step simulation of the faults events. Easy to use dashboard – if you see red go deeper. Detailed information about every relays stage on every step of simulation process
Base instrument for faults event investigation with some advanced tools
Automatically Protection selectivity and miscoordination check for 10000`s of calculations for all N-1, N-2 and specific contingency for power stations
Automatically Protection selectivity and miscoordination check for 1000`s of calculations for all N-1, N-2 and specific contingency for power stations
Automatically Protection selectivity and miscoordination check for 10000`s of calculations for all N-1, N-2 and specific contingency for grid
We support a lot of different interfaces and one of them bi-directional exchange with external systems by CIM.
Bi-directional data exchange with GIS and maintenance software systems
How do think, is it good idea to develop specific Facebook for protection engineers? Personalize but professional. Central database to store manufacturer specific control parameters, substation-related information, operational data
You can Import Relay’s configuration files in manufacturer formats to the safe place – centralized settings management system. You can trace settings changes and control states of settings lifecycle